Carrier 48fc 15 ton.

12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM14A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat els are in addition to the 3 to 5 ton models with SEERs up to 17.5 and 12.5 to 23 ton models with IEERs up to 19.1 to provide a full range offering. Ultra high efficiency With IEERs up to 20.8, these new WeatherExpert models help to contrib-ute in LEED credits and help qualify for rebates. The high IEER efficiencies are Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;Revit 1 is BIM (Building Information Modeling) software, developed by Autodesk 2. It allows you to design with both parametric 3D modeling and 2D drafting elements. Building Information Modeling is a Computer Aided Design (CAD) paradigm that employs intelligent 3D objects to represent real physical building components such as walls and doors.cable-ready for connection to the Carrier Comfort Network (CCN), Carrier i--Vu , and Third Party BACnet* building management systems. The control provides high-speed communications for remote monitoring via the Internet. Multiple units can be linked together (and to other Direct Digital Control (DDC) equipped units) using a 3-wire communication ...

New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit.

48FC units are single-packaged electric cooling, gas heating unit that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. Sizes 04-06 models use single-stage cooling capacity control. Size 07 models use two-stage cooling capacity control. FEATURES.

Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB. Carrier 48FC Series Pdf User Manuals. View online or download Carrier 48FC Series Installation Instructions. The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include:View and Download Carrier 48TC installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit Sizes 04-07 with Puron (R-410A) Refrigerant. 48TC air conditioner pdf manual download. Also for: 48tc-a04, 48tc-a05, 48tc-a06, 48tc-a07. Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat 14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only

Carrier

Specification. AHRI System Builder. Description. Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: …

S Two cooling stage models are available from 7.5 -- 15 ton. S SEER up to 13.0. S EER’s up to 11.1. S IEER’s up to 11.8. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time andWith Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn … 24 2 800 / 600 23000 12.0 15.0 30 2-1/2 1000 / 750 29000 12.0 15.0 36 3 1200 / 900 35400 12.5 16.0 42 3-1/2 1400 / 1050 42000 12.5 16.0 48 4 1600 / 1200 47500 12.3 16.0 60 5 1750 / 1200 57000 12.3 16.0 LEGEND dB ---Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of Performance View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download. ... Page 75 APPENDIX B — PHYSICAL DATA (cont) 48FC*(M,N)16 — 15 Ton — Physical Data ...This product has been superseded by. 48FCEA04A3A5-0A0A0 - 3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTUCarrier

New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit.Carrier West Training – HVAC TrainingCarrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES AND BENEFITS. Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)Gas Heating/Electric Cooling Models (48FC) 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3.Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat

10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability Available for …6 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...

View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) …There are already plenty of monopolies in big tech. Google isn't alone....GOOGL Alphabet Inc. (GOOGL) and its Google are playing scapegoat this Sunday. The tech giant is expect...Carrier has introduced Weather Series Rooftop Units with EcoBlueTM Technology. One of EcoBlue's many innovative features is the exclusive beltless direct-drive vane axial fan that replaces traditional belt drive fans with a simpler, more compact design for improved performance and efficiency while decreasing maintenance and installation costs. Item: 48FCEM07A2A50A0A0. Carrier 6 Ton, 11.0 EER Package RTU Medium Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,460/3. MFR: Item: 48FCEM07A2A60A0A0. Carrier 7.5 Ton, 11.2 EER Package RTU Medium Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,208/3. MFR: Item: 10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48fc-8-14-01si ; 48fcem 10t 208-230-3 ... Specifications. Brand ... View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) …We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ...Carrier’s new Gas Heat/ Electric Cooling WeatherExpert® 6 to 10 ton commercial packaged rooftop models are designed to provide total low cost of ownership by providing some of the highest cooling efficiencies in the industry, with low installed costs, low maintenance costs, and high reliability. These models focus on providing highView and Download Carrier WeatherMaker 48FC04-07 installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with Puron R-410A Refrigerant. ... The W7220 controller does not actually control the fan On single phase 48FC 3 to 5 ton units, if reduced the heat- speed or the heat output of the unit, and only ...

REPEAT PROCESS FOR 2 COMPRESSOR SYSTEMS. Carrier Corporation 2019. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480221-01 Printed in U.S.A. Form 48HC-7-12-06SI Pg CL-2 1-19 Replaces: 48HC-7-12-05SI.

1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard. 4. 48FC units comply with US Energy Policy Act (2005).

IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw …Air Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 …According to FEC filings, Donald Trump, the Republican nominee for president, raised $22 million last month. By clicking "TRY IT", I agree to receive newsletters and promotions fro...Revit 1 is BIM (Building Information Modeling) software, developed by Autodesk 2. It allows you to design with both parametric 3D modeling and 2D drafting elements. Building Information Modeling is a Computer Aided Design (CAD) paradigm that employs intelligent 3D objects to represent real physical building components such as walls and doors. 48TCED14A2A6-0A0A048 = Gas Heat Packaged RooftopTC = WeatherMaker™ Standard EfficiencyE = Medium HeatD = Two Stage Cooling Models 08-1614 = 12.5 tonsA = None2 = Belt Drive, Medium Static OptionA = Al/Cu - Al/Cu6 = 460/3/600 = Electromechanical Controls ca 48KC Sizes 04 to 06 Single Packaged Rooftop Units with Gas Heat. Product Data WeatherMaker®. Gas Heat/Electric Cooling Packaged Rooftop Units. 3 to 5 Nominal Tons. 2. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip screw” collars, handled access panels, and more we’ve made your unit easy to install ...All WeatherMaker 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unex-pected jobsite complications. Comfort control Carrier’s Round Tube Plate Fin coil design helps maximize heat transfer and reliable operation. 1. Third-party trademarks and logos are property of their respective owners.Carrier provides a full line of packaged rooftop equipment to meet demanding HVAC systems requirements, from small electric cooling units to large gas heat/electric cooling units like the WeatherExpert® series, which has the industry’s highest part-load performance IEER ratings in the 3-5 ton range. Carrier DOAS (Dedicated Outdoor Air Systems) are …CE - carrierenterprise.com

GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and …IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Carrier WeatherMaker rooftop unitView and Download Carrier 48FC M20 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 17.5-27.5 Nominal Tons. 48FC M20 Series air handlers pdf manual download. Also for: 48fc n20 series, 48fc m24...Instagram:https://instagram. dr steven houser obituaryhegemon group internationaleos 4th of july hours 2023lockpicking lawyer recommended locks SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Exclusive IGC solid-state control for on-board diagnostics ...Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor) bayfield inn live camis art moore still alive Replacement for. 48TCED08A2A6-0A0G0 - Gas Heat/Electric Cool Rooftop, 2-Stg 7.5T 460-3-60 Medium Fan; 48TCEM08A2A6-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTUSEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. lori wilson wsbtv 48TCED08A2A5-0A0G0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU; 48TCEM08A2A5-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTUCarrier Enterprise Mid-Atlantic Technical Support SiteInvestorPlace - Stock Market News, Stock Advice & Trading Tips To bears obsessed with “trees-in-the-forest” details like the yield... InvestorPlace - Stock Market N...